ORIGINAL PAPER
Durability Tests of Ball Valve Prototype with Flowmeter Operation
,
 
 
 
 
More details
Hide details
1
Wroclaw University of Technology Faculty of Mechanical and Power Engineering Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland
 
 
Online publication date: 2018-03-14
 
 
Publication date: 2018-02-01
 
 
International Journal of Applied Mechanics and Engineering 2018;23(1):235-249
 
KEYWORDS
ABSTRACT
The results of the investigation of the prototypical ball valve are presented in this article. The innovation of the tested valve is a ball with a built-in measuring orifice. The valve has been subjected to durability tests. Leakage under three temperatures: ambient, -30°C and +100°C was analyzed. Sealing elements of the valve were tested for roughness and deviation of shape before and after the cycles of operation. Ball valve operation means cycles of open/close. It was planned to perform 1000 cycles at each temperature condition accordingly. Tests of the valve were performed under gas pressure equal to 10 MPa. The research was carried out under the Operational Program “Intelligent Development” (POIR 01.01.01-00-0013 / 15 “Development of devices for measurement of media flow on industrial trunk-lines”.
REFERENCES (9)
1.
 
2.
naval-vexve-dn-10-250-welding-welding-en-din-3.pdf, opened 07.08.2017.
 
3.
“Ball valves” Andrex valve group, 2015.
 
4.
 
5.
Shpakov O.N. (2007): Truboprovodnaya armatura - spravochnik specialista. - Moscow.
 
6.
 
7.
 
8.
Nesbitt B. (2007): Handbook of Valves and Actuators. - Elsevier Science and Technology Books.
 
9.
Haffner M. (2015): ISO 15848 versus TA-Luft. - Fugitive Emission.
 